CLIA Kit for Syndecan 1 (SDC1) is a premium-quality life science research product supplied by Torvigen for laboratory and scientific applications.
Share
Product specifications
| Alternative Name | CD138; SDC; SYND1; Syndecan Proteoglycan 1 |
| Name Synonym | Syndecan 1 |
| Uniprot | P18827 |
| Field of Research | Tumor immunity; Infection immunity; Immunodeficiency |
| Applications | Chemiluminescent immunoassay for Antigen Detection. |
| Organism Species | Homo sapiens (Human) |
| Format | 48T, 96T, 96Tx5, 96Tx10, 96Tx100 |
| Specificity | This assay has high sensitivity and excellent specificity for detection of Syndecan 1 (SDC1) . No significant cross-reactivity or interference between Syndecan 1 (SDC1) and analogues was observed. |
| Sensitivity | The minimum detectable dose of this kit is typically less than 0.05ng/mL |
| Detection Range | 0.14-100ng/mL |
| Precision | Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level Syndecan 1 (SDC1) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level Syndecan 1 (SDC1) were tested on 3 different plates, 8 replicates in each plate. CV (%) = SD/meanX100 Intra-Assay: CV Inter-Assay: CV Inter-Assay: CV |
| Stability | The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end. |
| Assay Principle | The microplate provided in this kit has been pre-coated with an antibody specific to Syndecan 1 (SDC1) . Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Syndecan 1 (SDC1) . Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Syndecan 1 (SDC1) level in the sample or standard. |
| Assay Performance Time | 2h, 40min |
| Method | Double-antibody Sandwich |
| Sample Type | Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids |