Product specifications
| Alternative Name | GK; GLK; HHF3; HK4; HKIV; HXKP; MODY2; Hexokinase-D; Hexokinase 4; Maturity Onset Diabetes Of The Young 2 |
| Name Synonym | Glucokinase |
| Uniprot | P35557 |
| Field of Research | Enzyme & Kinase; Metabolic pathway; Endocrinology; Nutrition metabolism |
| Applications | Chemiluminescent immunoassay for Antigen Detection. |
| Organism Species | Homo sapiens (Human) |
| Format | 48T, 96T, 96Tx5, 96Tx10, 96Tx100 |
| Specificity | This assay has high sensitivity and excellent specificity for detection of Glucokinase (GCK) . No significant cross-reactivity or interference between Glucokinase (GCK) and analogues was observed. |
| Sensitivity | The minimum detectable dose of this kit is typically less than 0.08ng/mL |
| Detection Range | 0.21-150ng/mL |
| Precision | Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level Glucokinase (GCK) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level Glucokinase (GCK) were tested on 3 different plates, 8 replicates in each plate. CV (%) = SD/meanX100 Intra-Assay: CV Inter-Assay: CV Inter-Assay: CV |
| Stability | The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end. |
| Assay Principle | The microplate provided in this kit has been pre-coated with an antibody specific to Glucokinase (GCK) . Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Glucokinase (GCK) . Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Glucokinase (GCK) level in the sample or standard. |
| Assay Protocol |
1. Prepare all reagents, samples and standards; 2. Add 100µ L standard or sample to each well. Incubate 2 hours at 37° C; 3. Aspirate and add 100µ L prepared Detection Reagent A. Incubate 1 hour at 37° C; 4. Aspirate and wash 3 times; 5. Add 100µ L prepared Detection Reagent B. Incubate 30 minutes at 37° C; 6. Aspirate and wash 5 times; 7. Add 100µ L Substrate Solution. Incubate 10 minutes at 37° C; 8. Read RLU value immediately. |
| Assay Performance Time | 2h, 40min |
| Method | Double-antibody Sandwich |
| Sample Type | Serum, plasma, tissue homogenates and other biological fluids |